Induced-draught crossflow towers built for continuous industrial duty in Saudi ambient conditions, with every wearing component available separately.
- Draught type
- Induced draught, crossflow
- Configuration
- Single and multi-cell
- Fan drive
- Belt or gear drive, optional VFD
- Water distribution
- Open gravity basin with removable nozzles
Figures are indicative. Sizes, materials and duty are confirmed against your drawing and a site survey before quotation. Part of our Evaporative Condensers & Cooling Towers service line, so we supply, install and maintain it.
What it does
Air moves horizontally through the fill while water falls vertically through it. The distribution basin sits open at the top, so nozzles and fill can be inspected and cleaned without breaking into pressurised pipework or taking the casing apart. A tower that is awkward to inspect does not get inspected, and fouled fill is the most common reason a tower quietly stops meeting its duty.
Selection is made against the site's design wet bulb, not a nominal catalogue figure.
Specification
| Draught type | Induced draught, crossflow |
|---|---|
| Configuration | Single and multi-cell |
| Fan drive | Belt or gear drive, optional VFD |
| Water distribution | Open gravity basin with removable nozzles |
| Fill | PVC film fill, replaceable in packs |
| Drift eliminators | PVC, three-pass |
| Selection basis | Site design wet bulb |
Materials of construction
| Casing | Hot-dip galvanised steel; FRP and stainless options |
|---|---|
| Cold water basin | Galvanised steel or FRP |
| Fill and eliminators | PVC |
| Fasteners | Stainless steel |
Where it fits
- Process cooling
- Chiller condenser water
- Steel and heavy manufacturing
- Food processing
- Power generation
- District cooling
Options and accessories
- Variable-frequency fan drive
- Stainless steel basin
- FRP casing for coastal sites
- Basin heaters
- Ladder and handrail access
- Vibration switch
Related equipment
From the same range, and the plant it usually works alongside.

Cooling Towers
SSS Modular Cooling Tower
Modular towers for light commercial and process duty

Cooling Towers
Closed-Circuit Cooling Tower
Sealed coil for water or glycol, 100–1,200 TR per cell

Cooling Towers
Evaporative Condenser
150–2,500 kW per unit for ammonia, HFC and HFO

Air-Cooled Equipment
Air-Cooled Condenser
5 kW to 10,000 kW+ with zero water consumption
Send the duty, we'll size the unit
Send the duty, the site conditions and any existing nameplate data. An engineer replies with questions first, then a costed selection.